Export limit exceeded: 55646 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (55646 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-57513 2026-04-15 6.5 Medium
A floating-point exception (FPE) vulnerability exists in the AP4_TfraAtom::AP4_TfraAtom function in Bento4.
CVE-2024-13503 2026-04-15 N/A
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in Newtec NTC2218, NTC2250, NTC2299 on Linux, PowerPC, ARM (Updating signaling process in the swdownload binary modules) allows Local Execution of Code, Remote Code Inclusion. This issue affects NTC2218, NTC2250, NTC2299: from 1.0.1.1 through 2.2.6.19. The issue is both present on the PowerPC versions of the modem and the ARM versions. A stack buffer buffer overflow in the swdownload binary allows attackers to execute arbitrary code. The parse_INFO function uses an unrestricted `sscanf` to read a string of an incoming network packet into a statically sized buffer.
CVE-2024-57510 2026-04-15 7.8 High
Buffer Overflow vulnerability in Bento4 mp42avc v.3bdc891602d19789b8e8626e4a3e613a937b4d35 allows a local attacker to execute arbitrary code via the AP4_MemoryByteStream::WritePartial.
CVE-2024-57509 2026-04-15 7.8 High
Buffer Overflow vulnerability in Bento4 mp42avc v.3bdc891602d19789b8e8626e4a3e613a937b4d35 allows a local attacker to execute arbitrary code via the AP4_File::ParseStream and related functions.
CVE-2024-57375 2026-04-15 2.4 Low
Andamiro Pump It Up 20th Anniversary (aka Double X or XX/2019) 1.00.0-2.08.3 allows a physically proximate attacker to cause a denial of service (application crash) via certain deselect actions.
CVE-2024-1848 2026-04-15 7.8 High
Heap-based Buffer Overflow, Memory Corruption, Out-Of-Bounds Read, Out-Of-Bounds Write, Stack-based Buffer Overflow, Type Confusion, Uninitialized Variable, Use-After-Free vulnerabilities exist in the file reading procedure in SOLIDWORKS Desktop on Release SOLIDWORKS 2024. These vulnerabilities could allow an attacker to execute arbitrary code while opening a specially crafted CATPART, DWG, DXF, IPT, JT, SAT, SLDDRW, SLDPRT, STL, STP, X_B or X_T file.
CVE-2023-31331 2026-04-15 3 Low
Improper access control in the DRTM firmware could allow a privileged attacker to perform multiple driver initializations, resulting in stack memory corruption that could potentially lead to loss of integrity or availability.
CVE-2024-1916 2026-04-15 9.8 Critical
Integer Overflow or Wraparound vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series and MELSEC-L Series CPU modules allows a remote unauthenticated attacker to execute malicious code on a target product by sending a specially crafted packet.
CVE-2024-1917 2026-04-15 9.8 Critical
Integer Overflow or Wraparound vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series and MELSEC-L Series CPU modules allows a remote unauthenticated attacker to execute malicious code on a target product by sending a specially crafted packet.
CVE-2023-31330 1 Amd 8 Athlon, Athlon 3000, Ryzen 3000 and 5 more 2026-04-15 2.5 Low
An out-of-bounds read in the ASP could allow a privileged attacker with access to a malicious bootloader to potentially read sensitive memory resulting in loss of confidentiality.
CVE-2024-29948 2026-04-15 3.8 Low
There is an out-of-bounds read vulnerability in some Hikvision NVRs. An authenticated attacker could exploit this vulnerability by sending specially crafted messages to a vulnerable device, causing a service abnormality.
CVE-2024-29857 2 Bouncycastle, Redhat 8 Bc-fja, Bc-java, Bc C .net and 5 more 2026-04-15 7.5 High
An issue was discovered in ECCurve.java and ECCurve.cs in Bouncy Castle Java (BC Java) before 1.78, BC Java LTS before 2.73.6, BC-FJA before 1.0.2.5, and BC C# .Net before 2.3.1. Importing an EC certificate with crafted F2m parameters can lead to excessive CPU consumption during the evaluation of the curve parameters.
CVE-2024-1969 2026-04-15 8.2 High
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in Secomea GateManager (webserver modules) allows crash of GateManager.This issue affects GateManager: from 9.7 before 11.2.624095033.
CVE-2024-57262 1 Pengutronix 1 Barebox 2026-04-15 7.1 High
In barebox before 2025.01.0, ext4fs_read_symlink has an integer overflow for zalloc (adding one to an le32 variable) via a crafted ext4 filesystem with an inode size of 0xffffffff, resulting in a malloc of zero and resultant memory overwrite, a related issue to CVE-2024-57256.
CVE-2024-57261 1 Pengutronix 1 Barebox 2026-04-15 7.1 High
In barebox before 2025.01.0, request2size in common/dlmalloc.c has an integer overflow, a related issue to CVE-2024-57258.
CVE-2024-2824 2026-04-15 6.3 Medium
A vulnerability was found in Matthias-Wandel jhead 3.08 and classified as critical. This issue affects the function PrintFormatNumber of the file exif.c. The manipulation leads to heap-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257711.
CVE-2024-2103 2026-04-15 6.5 Medium
Inclusion of undocumented features vulnerability accessible when logged on with a privileged access level on the following Schweitzer Engineering Laboratories relays could allow the relay to behave unpredictably: SEL-700BT Motor Bus Transfer Relay, SEL-700G Generator Protection Relay, SEL-710-5 Motor Protection Relay, SEL-751 Feeder Protection Relay, SEL-787-2/-3/-4 Transformer Protection Relay, SEL-787Z High-Impedance Differential Relay . See product instruction manual appendix A dated 20240308 for more details regarding the SEL-751 Feeder Protection Relay. For more information for the other affected products, see their instruction manuals dated 20240329.
CVE-2024-28093 1 Adtran 1 Netvanta 3120 Firmware 2026-04-15 8.8 High
The TELNET service of AdTran NetVanta 3120 18.01.01.00.E devices is enabled by default, and has default credentials for a root-level account.
CVE-2024-28051 2026-04-15 2.2 Low
Out-of-bounds read in some Intel(R) VPL software before version 24.1.4 may allow an authenticated user to potentially enable information disclosure via local access.
CVE-2024-28042 2026-04-15 8.4 High
SUBNET Solutions Inc. has identified vulnerabilities in third-party components used in PowerSYSTEM Center.