Export limit exceeded: 55598 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (55598 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-2851 | 2026-04-15 | 8 High | ||
| A vulnerability classified as critical has been found in GL.iNet GL-A1300 Slate Plus, GL-AR300M16 Shadow, GL-AR300M Shadow, GL-AR750 Creta, GL-AR750S-EXT Slate, GL-AX1800 Flint, GL-AXT1800 Slate AX, GL-B1300 Convexa-B, GL-B3000 Marble, GL-BE3600 Slate 7, GL-E750, GL-E750V2 Mudi, GL-MT300N-V2 Mango, GL-MT1300 Beryl, GL-MT2500 Brume 2, GL-MT3000 Beryl AX, GL-MT6000 Flint 2, GL-SFT1200 Opal, GL-X300B Collie, GL-X750 Spitz, GL-X3000 Spitz AX, GL-XE300 Puli and GL-XE3000 Puli AX 4.x. Affected is an unknown function of the file plugins.so of the component RPC Handler. The manipulation leads to buffer overflow. It is recommended to upgrade the affected component. | ||||
| CVE-2025-29069 | 2026-04-15 | 7.3 High | ||
| A heap buffer overflow vulnerability has been identified in the lcms2-2.16. The vulnerability exists in the UnrollChunkyBytes function in cmspack.c, which is responsible for handling color space transformations. NOTE: this is disputed by the Supplier because the finding identified a bug in a third-party calling program, not in lcms. | ||||
| CVE-2025-29070 | 2026-04-15 | 7.5 High | ||
| A heap buffer overflow vulnerability has been identified in thesmooth2() in cmsgamma.c in lcms2-2.16 which allows a remote attacker to cause a denial of service. NOTE: the Supplier disputes this because "this is not exploitable as this function is never called on normal color management, is there only as a helper for low-level programming and investigation." | ||||
| CVE-2025-29476 | 2026-04-15 | 5.5 Medium | ||
| Buffer Overflow vulnerability in compress_chunk_fuzzer with oss-fuzz on commit 16450518afddcb3139de627157208e49bfef6987 in c-blosc2 v.2.17.0 and before. | ||||
| CVE-2025-30742 | 2026-04-15 | 5.3 Medium | ||
| httpd.c in atophttpd 2.8.0 has an off-by-one error and resultant out-of-bounds read because a certain 1024-character req string would not have a final '\0' character. | ||||
| CVE-2025-31929 | 2026-04-15 | 4.2 Medium | ||
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code. | ||||
| CVE-2025-31930 | 2026-04-15 | 8.8 High | ||
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. | ||||
| CVE-2025-3194 | 2026-04-15 | 7.5 High | ||
| Versions of the package bigint-buffer from 0.0.0 are vulnerable to Buffer Overflow in the toBigIntLE() function. Attackers can exploit this to crash the application. | ||||
| CVE-2025-32014 | 2026-04-15 | N/A | ||
| estree-util-value-to-estree converts a JavaScript value to an ESTree expression. When generating an ESTree from a value with a property named __proto__, valueToEstree would generate an object that specifies a prototype instead. This vulnerability is fixed in 3.3.3. | ||||
| CVE-2025-32029 | 2026-04-15 | N/A | ||
| ts-asn1-der is a collection of utility classes to encode ASN.1 data following DER rule. Incorrect number DER encoding can lead to denial on service for absolute values in the range 2**31 -- 2**32 - 1. The arithmetic in the numBitLen didn't take into account that values in this range could result in a negative result upon applying the >> operator, leading to an infinite loop. The issue is patched in version 1.0.4. If upgrading is not an option, the issue can be mitigated by validating inputs to Asn1Integer to ensure that they are not smaller than -2**31 + 1 and no larger than 2**31 - 1. | ||||
| CVE-2025-32056 | 1 Bosch | 1 Infotainment System Ecu | 2026-04-15 | 4 Medium |
| The anti-theft protection mechanism can be bypassed by attackers due to weak response generation algorithms for the head unit. It is possible to reveal all 32 corresponding responses by sniffing CAN traffic or by pre-calculating the values, which allow to bypass the protection. First identified on Nissan Leaf ZE1 manufactured in 2020. | ||||
| CVE-2025-32058 | 1 Bosch | 1 Infotainment System Ecu | 2026-04-15 | 9.3 Critical |
| The Infotainment ECU manufactured by Bosch uses a RH850 module for CAN communication. RH850 is connected to infotainment over the INC interface through a custom protocol. There is a vulnerability during processing requests of this protocol on the V850 side which allows an attacker with code execution on the infotainment main SoC to perform code execution on the RH850 module and subsequently send arbitrary CAN messages over the connected CAN bus. First identified on Nissan Leaf ZE1 manufactured in 2020. | ||||
| CVE-2025-32059 | 1 Bosch | 1 Infotainment System Ecu | 2026-04-15 | 8.8 High |
| The specific flaw exists within the Bluetooth stack developed by Alps Alpine of the Infotainment ECU manufactured by Bosch. The issue results from the lack of proper boundary validation of user-supplied data, which can result in a stack-based buffer overflow when receiving a specific packet on the established upper layer L2CAP channel. An attacker can leverage this vulnerability to obtain remote code execution on the Infotainment ECU with root privileges. First identified on Nissan Leaf ZE1 manufactured in 2020. | ||||
| CVE-2025-32061 | 1 Bosch | 1 Infotainment System Ecu | 2026-04-15 | 8.8 High |
| The specific flaw exists within the Bluetooth stack developed by Alps Alpine of the Infotainment ECU manufactured by Bosch. The issue results from the lack of proper boundary validation of user-supplied data, which can result in a stack-based buffer overflow when receiving a specific packet on the established upper layer L2CAP channel. An attacker can leverage this vulnerability to obtain remote code execution on the Infotainment ECU with root privileges. First identified on Nissan Leaf ZE1 manufactured in 2020. | ||||
| CVE-2025-32062 | 1 Bosch | 1 Infotainment System Ecu | 2026-04-15 | 8.8 High |
| The specific flaw exists within the Bluetooth stack developed by Alps Alpine of the Infotainment ECU manufactured by Bosch. The issue results from the lack of proper boundary validation of user-supplied data, which can result in a stack-based buffer overflow when receiving a specific packet on the established upper layer L2CAP channel. An attacker can leverage this vulnerability to obtain remote code execution on the Infotainment ECU with root privileges. First identified on Nissan Leaf ZE1 manufactured in 2020. | ||||
| CVE-2025-32072 | 2026-04-15 | N/A | ||
| Improper Encoding or Escaping of Output vulnerability in The Wikimedia Foundation Mediawiki Core - Feed Utils allows WebView Injection.This issue affects Mediawiki Core - Feed Utils: from 1.39 through 1.43. | ||||
| CVE-2025-32078 | 2026-04-15 | N/A | ||
| Improper Encoding or Escaping of Output vulnerability in The Wikimedia Foundation Mediawiki - Version Compare Extension allows Cross-Site Scripting (XSS).This issue affects Mediawiki - Version Compare Extension: from 1.39 through 1.43. | ||||
| CVE-2025-32089 | 2 Broadcom, Dell | 2 Bcm5820x, Controlvault3 | 2026-04-15 | 8.8 High |
| A buffer overflow vulnerability exists in the CvManager_SBI functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted ControlVault API call can lead to a arbitrary code execution. An attacker can issue an api call to trigger this vulnerability. | ||||
| CVE-2025-33218 | 1 Nvidia | 6 Geforce, Gpu Display Driver, Quadro and 3 more | 2026-04-15 | 7.8 High |
| NVIDIA GPU Display Driver for Windows contains a vulnerability in the kernel mode layer (nvlddmkm.sys), where an attacker could cause an integer overflow. A successful exploit of this vulnerability might lead to code execution, escalation of privileges, data tampering, denial of service, or information disclosure. | ||||
| CVE-2025-3496 | 2026-04-15 | 7.5 High | ||
| An unauthenticated remote attacker can cause a buffer overflow which could lead to unexpected behaviour or DoS via Bluetooth or RS-232 interface. | ||||