Export limit exceeded: 94642 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (94642 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2019-6588 | 1 Liferay | 1 Liferay Portal | 2024-11-21 | N/A |
| In Liferay Portal before 7.1 CE GA4, an XSS vulnerability exists in the SimpleCaptcha API when custom code passes unsanitized input into the "url" parameter of the JSP taglib call <liferay-ui:captcha url="<%= url %>" /> or <liferay-captcha:captcha url="<%= url %>" />. Liferay Portal out-of-the-box behavior with no customizations is not vulnerable. | ||||
| CVE-2019-6585 | 1 Siemens | 8 Scalance S602, Scalance S602 Firmware, Scalance S612 and 5 more | 2024-11-21 | 6.1 Medium |
| A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. | ||||
| CVE-2019-6579 | 1 Siemens | 1 Spectrum Power 4 | 2024-11-21 | 9.8 Critical |
| A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known. | ||||
| CVE-2019-6577 | 1 Siemens | 22 Simatic Hmi Comfort Outdoor Panels, Simatic Hmi Comfort Outdoor Panels Firmware, Simatic Hmi Comfort Panels and 19 more | 2024-11-21 | N/A |
| A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known. | ||||
| CVE-2019-6572 | 1 Siemens | 22 Simatic Hmi Comfort Outdoor Panels, Simatic Hmi Comfort Outdoor Panels Firmware, Simatic Hmi Comfort Panels and 19 more | 2024-11-21 | 9.1 Critical |
| A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. | ||||
| CVE-2019-6565 | 1 Moxa | 8 Eds-405a, Eds-405a Firmware, Eds-408a and 5 more | 2024-11-21 | 6.1 Medium |
| Moxa IKS and EDS fails to properly validate user input, giving unauthenticated and authenticated attackers the ability to perform XSS attacks, which may be used to send a malicious script. | ||||
| CVE-2019-6562 | 1 Philips | 1 Tasy Emr | 2024-11-21 | 5.4 Medium |
| In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users. | ||||
| CVE-2019-6553 | 1 Rockwellautomation | 1 Rslinx | 2024-11-21 | 9.8 Critical |
| A vulnerability was found in Rockwell Automation RSLinx Classic versions 4.10.00 and prior. An input validation issue in a .dll file of RSLinx Classic where the data in a Forward Open service request is passed to a fixed size buffer, allowing an attacker to exploit a stack-based buffer overflow condition. | ||||
| CVE-2019-6552 | 1 Advantech | 1 Webaccess | 2024-11-21 | 9.8 Critical |
| Advantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple command injection vulnerabilities, caused by a lack of proper validation of user-supplied data, may allow remote code execution. | ||||
| CVE-2019-6550 | 1 Advantech | 1 Webaccess | 2024-11-21 | 9.8 Critical |
| Advantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple stack-based buffer overflow vulnerabilities, caused by a lack of proper validation of the length of user-supplied data, may allow remote code execution. | ||||
| CVE-2019-6548 | 1 Ge | 1 Ge Communicator | 2024-11-21 | 9.8 Critical |
| GE Communicator, all versions prior to 4.0.517, contains two backdoor accounts with hardcoded credentials, which may allow control over the database. This service is inaccessible to attackers if Windows default firewall settings are used by the end user. | ||||
| CVE-2019-6541 | 1 We-con | 1 Levistudiou | 2024-11-21 | 7.8 High |
| A memory corruption vulnerability has been identified in WECON LeviStudioU version 1.8.56 and prior, which may allow arbitrary code execution. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC. | ||||
| CVE-2019-6539 | 1 We-con | 1 Levistudiou | 2024-11-21 | 7.8 High |
| Several heap-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior have been identified, which may allow arbitrary code execution. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC. | ||||
| CVE-2019-6537 | 1 We-con | 1 Levistudiou | 2024-11-21 | 7.8 High |
| Multiple stack-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior may be exploited when parsing strings within project files. The process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage these vulnerabilities to execute code under the context of the current process. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC. | ||||
| CVE-2019-6536 | 1 Lcds | 1 Laquis Scada | 2024-11-21 | N/A |
| Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process. | ||||
| CVE-2019-6530 | 1 Panasonic | 1 Control Fpwin Pro | 2024-11-21 | 7.8 High |
| Panasonic FPWIN Pro version 7.3.0.0 and prior allows attacker-created project files to be loaded by an authenticated user causing heap-based buffer overflows, which may lead to remote code execution. | ||||
| CVE-2019-6528 | 1 Psigridconnect | 10 Iec104 Security Proxy, Iec104 Security Proxy Firmware, Smart Telecontrol Unit Tcg and 7 more | 2024-11-21 | 8.8 High |
| PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code. | ||||
| CVE-2019-6504 | 1 Broadcom | 1 Automic Workload Automation | 2024-11-21 | N/A |
| Insufficient output sanitization in the Automic Web Interface (AWI), in CA Automic Workload Automation 12.0 to 12.2, allow attackers to potentially conduct persistent cross site scripting (XSS) attacks via a crafted object. | ||||
| CVE-2019-6501 | 3 Fedoraproject, Qemu, Redhat | 5 Fedora, Qemu, Enterprise Linux and 2 more | 2024-11-21 | N/A |
| In QEMU 3.1, scsi_handle_inquiry_reply in hw/scsi/scsi-generic.c allows out-of-bounds write and read operations. | ||||
| CVE-2019-6499 | 1 Teradata | 1 Viewpoint | 2024-11-21 | N/A |
| Teradata Viewpoint before 14.0 and 16.20.00.02-b80 contains a hardcoded password of TDv1i2e3w4 for the viewpoint database account (in viewpoint-portal\conf\server.xml) that could potentially be exploited by malicious users to compromise the affected system. | ||||