| CVE-2025-12052 | 1 Insyde | 1 Insydeh2o | 2026-04-15 | 7.8 High |
| The drivers in the tool packages use RTL_QUERY_REGISTRY_DIRECT flag to read a registry value to which an untrusted user-mode application may be able to cause a buffer overflow. | ||||
| CVE-2025-2071 | 2026-04-15 | N/A | ||
| A critical OS Command Injection vulnerability has been identified in the FAST LTA Silent Brick WebUI, allowing remote attackers to execute arbitrary operating system commands via specially crafted input. This vulnerability arises due to improper handling of untrusted input, which is passed directly to system-level commands without adequate sanitization or validation. Successful exploitation could allow attackers to execute arbitrary commands on the affected system, potentially resulting in unauthorized access, data leakage, or full system compromise. Affected WebUI parameters are "hd" and "pi". | ||||
| CVE-2025-2983 | 2026-04-15 | 5.5 Medium | ||
| A vulnerability has been found in Legrand SMS PowerView 1.x and classified as critical. Affected by this vulnerability is an unknown functionality. The manipulation of the argument redirect leads to os command injection. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-37168 | 2026-04-15 | 5.3 Medium | ||
| @grpc/grps-js implements the core functionality of gRPC purely in JavaScript, without a C++ addon. Prior to versions 1.10.9, 1.9.15, and 1.8.22, there are two separate code paths in which memory can be allocated per message in excess of the `grpc.max_receive_message_length` channel option: If an incoming message has a size on the wire greater than the configured limit, the entire message is buffered before it is discarded; and/or if an incoming message has a size within the limit on the wire but decompresses to a size greater than the limit, the entire message is decompressed into memory, and on the server is not discarded. This has been patched in versions 1.10.9, 1.9.15, and 1.8.22. | ||||
| CVE-2024-22033 | 2026-04-15 | 6.3 Medium | ||
| The OBS service obs-service-download_url was vulnerable to a command injection vulnerability. The attacker could provide a configuration to the service that allowed to execute command in later steps | ||||
| CVE-2024-20295 | 1 Cisco | 1 Integrated Management Controller | 2026-04-15 | 8.8 High |
| A vulnerability in the CLI of the Cisco Integrated Management Controller (IMC) could allow an authenticated, local attacker to perform command injection attacks on the underlying operating system and elevate privileges to root. To exploit this vulnerability, the attacker must have read-only or higher privileges on an affected device. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by submitting a crafted CLI command. A successful exploit could allow the attacker to elevate privileges to root. | ||||
| CVE-2025-59733 | 1 Ffmpeg | 1 Ffmpeg | 2026-04-15 | 6.5 Medium |
| When decoding an OpenEXR file that uses DWAA or DWAB compression, there's an implicit assumption that all image channels have the same pixel type (and size), and that if there are four channels, the first four are "B", "G", "R" and "A". The channel parsing code can be found in decode_header. The buffer td->uncompressed_data is allocated in decode_block based on the xsize, ysize and computed current_channel_offset. The function dwa_uncompress then assumes at [5] that if there are 4 channels, these are "B", "G", "R" and "A", and in the calculations at [6] and [7] that all channels are of the same type, which matches the type of the main color channels. If we set the main color channels to a 4-byte type and add duplicate or unknown channels of the 2-byte EXR_HALF type, then the addition at [7] will increment the pointer by 4-bytes * xsize * nb_channels, which will exceed the allocated buffer. We recommend upgrading to version 8.0 or beyond. | ||||
| CVE-2024-11983 | 1 Billion Electric | 4 M100, M120n, M150 and 1 more | 2026-04-15 | 7.2 High |
| Certain models of routers from Billion Electric has an OS Command Injection vulnerability, allowing remote attackers with administrator privileges to inject arbitrary system commands into a specific SSH function and execute them on the device. | ||||
| CVE-2024-12248 | 2026-04-15 | 9.8 Critical | ||
| Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution. | ||||
| CVE-2024-12668 | 2026-04-15 | 8.2 High | ||
| Velocidex WinPmem versions below 4.1 suffer from an Out of Bounds Write vulnerability. By using an IO Control, a user space program can trick the driver into writing a 0 into any chosen memory location. In conjunction with information leakage from the WinPmem driver, attackers can discover the location in memory for the g_CiOptions global symbol. This can be leveraged to disable signed driver enforcement on the target system - allowing attackers to load unsigned drivers. | ||||
| CVE-2024-12985 | 2026-04-15 | 6.3 Medium | ||
| A vulnerability classified as critical was found in Overtek OT-E801G OTE801G65.1.1.0. This vulnerability affects unknown code of the file /diag_ping.cmd?action=test&interface=ppp0.1&ipaddr=8.8.8.8%26%26cat%20/etc/passwd&ipversion=4&sessionKey=test. The manipulation leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-13089 | 2026-04-15 | 7.2 High | ||
| An OS command injection vulnerability within the update functionality may allow an authenticated administrator to execute unauthorized arbitrary OS commands. Users with administrative privileges may upload update packages to upgrade the versions of Nozomi Networks Guardian and CMC. While these updates are signed and their signatures are validated prior to installation, an improper signature validation check has been identified. This issue could potentially enable users to execute commands remotely on the appliance, thereby impacting confidentiality, integrity, and availability. | ||||
| CVE-2024-13129 | 1 Roxy-wi | 1 Roxy-wi | 2026-04-15 | 8.8 High |
| A vulnerability was found in Roxy-WI up to 8.1.3. It has been declared as critical. Affected by this vulnerability is the function action_service of the file app/modules/roxywi/roxy.py. The manipulation of the argument action/service leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 8.1.4 is able to address this issue. The identifier of the patch is 32313928eb9ce906887b8a30bf7b9a3d5c0de1be. It is recommended to upgrade the affected component. | ||||
| CVE-2024-1628 | 2026-04-15 | 8.4 High | ||
| OS command injection vulnerabilities in GE HealthCare ultrasound devices | ||||
| CVE-2024-1655 | 2026-04-15 | 8.8 High | ||
| Certain ASUS WiFi routers models has an OS Command Injection vulnerability, allowing an authenticated remote attacker to execute arbitrary system commands by sending a specially crafted request. | ||||
| CVE-2024-1848 | 2026-04-15 | 7.8 High | ||
| Heap-based Buffer Overflow, Memory Corruption, Out-Of-Bounds Read, Out-Of-Bounds Write, Stack-based Buffer Overflow, Type Confusion, Uninitialized Variable, Use-After-Free vulnerabilities exist in the file reading procedure in SOLIDWORKS Desktop on Release SOLIDWORKS 2024. These vulnerabilities could allow an attacker to execute arbitrary code while opening a specially crafted CATPART, DWG, DXF, IPT, JT, SAT, SLDDRW, SLDPRT, STL, STP, X_B or X_T file. | ||||
| CVE-2024-20496 | 1 Cisco | 2 Sd-wan Vedge Cloud, Sd-wan Vedge Router | 2026-04-15 | 6.1 Medium |
| A vulnerability in the UDP packet validation code of Cisco SD-WAN vEdge Software could allow an unauthenticated, adjacent attacker to cause a denial of service (DoS) condition on an affected system. This vulnerability is due to incorrect handling of a specific type of malformed UDP packet. An attacker in a machine-in-the-middle position could exploit this vulnerability by sending crafted UDP packets to an affected device. A successful exploit could allow the attacker to cause the device to reboot, resulting in a DoS condition on the affected system. | ||||
| CVE-2025-9974 | 1 Nokia | 1 Nokia Ont | 2026-04-15 | 8 High |
| The unified WEBUI application of the ONT/Beacon device contains an input handling flaw that allows authenticated users to trigger unintended system-level command execution. Due to insufficient validation of user-supplied data, a low-privileged authenticated attacker may be able to execute arbitrary commands on the underlying ONT/Beacon operating system, potentially impacting the confidentiality, integrity, and availability of the device. | ||||
| CVE-2024-27172 | 1 Toshibatec | 50 E-studio-2010-ac, E-studio-2015-nc, E-studio-2018 A and 47 more | 2026-04-15 | 9.8 Critical |
| Remote Command program allows an attacker to get Remote Code Execution. As for the affected products/models/versions, see the reference URL. | ||||
| CVE-2024-2742 | 2026-04-15 | 6.4 Medium | ||
| Operating system command injection vulnerability in Planet IGS-4215-16T2S, affecting firmware version 1.305b210528. An authenticated attacker could execute arbitrary code on the remote host by exploiting IP address functionality. | ||||