Export limit exceeded: 17056 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (17056 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-59936 1 Nearform 1 Get-jwks 2026-04-15 N/A
get-jwks contains fetch utils for JWKS keys. In versions prior to 11.0.2, a vulnerability in get-jwks can lead to cache poisoning in the JWKS key-fetching mechanism. When the iss (issuer) claim is validated only after keys are retrieved from the cache, it is possible for cached keys from an unexpected issuer to be reused, resulting in a bypass of issuer validation. This design flaw enables a potential attack where a malicious actor crafts a pair of JWTs, the first one ensuring that a chosen public key is fetched and stored in the shared JWKS cache, and the second one leveraging that cached key to pass signature validation for a targeted iss value. The vulnerability will work only if the iss validation is done after the use of get-jwks for keys retrieval. This issue has been patched in version 11.0.2.
CVE-2025-53094 2026-04-15 N/A
ESPAsyncWebServer is an asynchronous HTTP and WebSocket server library for ESP32, ESP8266, RP2040 and RP2350. In versions up to and including 3.7.8, a CRLF (Carriage Return Line Feed) injection vulnerability exists in the construction and output of HTTP headers within `AsyncWebHeader.cpp`. Unsanitized input allows attackers to inject CR (`\r`) or LF (`\n`) characters into header names or values, leading to arbitrary header or response manipulation. Manipulation of HTTP headers and responses can enable a wide range of attacks, making the severity of this vulnerability high. A fix is available at pull request 211 and is expected to be part of version 3.7.9.
CVE-2025-53007 2026-04-15 N/A
arduino-esp32 provides an Arduino core for the ESP32. Versions prior to 3.3.0-RC1 and 3.2.1 contain a HTTP Response Splitting vulnerability. The `sendHeader` function takes arbitrary input for the HTTP header name and value, concatenates them into an HTTP header line, and appends this to the outgoing HTTP response headers. There is no validation or sanitization of the `name` or `value` parameters before they are included in the HTTP response. If an attacker can control the input to `sendHeader` (either directly or indirectly), they could inject carriage return (`\r`) or line feed (`\n`) characters into either the header name or value. This could allow the attacker to inject additional headers, manipulate the structure of the HTTP response, potentially inject an entire new HTTP response (HTTP Response Splitting), and/or ause header confusion or other HTTP protocol attacks. Versions 3.3.0-RC1 and 3.2.1 contain a fix for the issue.
CVE-2025-49846 2026-04-15 N/A
wire-ios is an iOS client for the Wire secure messaging application. From Wire iOS 3.111.1 to before 3.124.1, messages that were visible in the view port have been logged to the iOS system logs in clear text. Wire application logs created and managed by the application itself were not affected, especially not the logs users can export and send to Wire support. The iOS logs can only be accessed if someone had (physical) access to the underlying unlocked device. The issue manifested itself by calling canOpenUrl() and passing an invalid URL object. When iOS then performs the check and fails, it logs the contents to the system log. This is not documented behaviour. Wire released an emergency fix with version 3.124.1. As a workaround, users can reset their iOS device to remove the offending logs. Since Wire cannot access or modify iOS system logs, there's no other workaround other than a reset.
CVE-2025-46333 2026-04-15 N/A
z2d is a pure Zig 2D graphics library. Versions of z2d after `0.5.1` and up to and including `0.6.0`, when writing from one surface to another using `z2d.compositor.StrideCompositor.run`, and higher-level operations when the anti-aliasing mode is set to `.default` (such as `Context.fill`, `Context.stroke`, `painter.fill`, and `painter.stroke`), the source surface can be completely out-of-bounds on the x-axis, but not on the y-axis, by way of a negative offset. This results in an overflow of the value controlling the length of the stride. In non-safe optimization modes (consumers compiling with `ReleaseFast` or `ReleaseSmall`), this could potentially lead to invalid memory accesses or corruption. This issue is patched in version `0.6.1`. Users on an untagged version after `v0.5.1` and before `v0.6.1` are advised to update to address the vulnerability. Those still on Zig `0.13.0` are recommended to downgrade to `v0.5.1`.
CVE-2025-3588 2026-04-15 5.3 Medium
A vulnerability, which was classified as problematic, has been found in joelittlejohn jsonschema2pojo 1.2.2. This issue affects the function apply of the file org/jsonschema2pojo/rules/SchemaRule.java of the component JSON File Handler. The manipulation leads to stack-based buffer overflow. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-3497 2026-04-15 8.7 High
The Linux distribution underlying the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) is obsolete and reached end of life (EOL) on June 30, 2024. Thus, any unmitigated vulnerability could be exploited to affect this product.
CVE-2024-4231 2026-04-15 4.6 Medium
This vulnerability exists in Digisol Router (DG-GR1321: Hardware version 3.7L; Firmware version : v3.2.02) due to presence of root terminal access on a serial interface without proper access control. An attacker with physical access could exploit this by identifying UART pins and accessing the root shell on the vulnerable system. Successful exploitation of this vulnerability could allow the attacker to access the sensitive information on the targeted system.
CVE-2024-41995 1 Ricoh Company Ltd 1 Javatm Platform 2026-04-15 7.5 High
Initialization of a resource with an insecure default vulnerability exists in JavaTM Platform Ver.12.89 and earlier. If this vulnerability is exploited, the product may be affected by some known TLS1.0 and TLS1.1 vulnerabilities. As for the specific products/models/versions of MFPs and printers that contain JavaTM Platform, see the information provided by the vendor.
CVE-2024-41975 2026-04-15 5.3 Medium
An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-6751 1 Linksys 1 E8450 2026-04-15 8.8 High
A vulnerability, which was classified as critical, was found in Linksys E8450 up to 1.2.00.360516. This affects the function set_device_language of the file portal.cgi of the component HTTP POST Request Handler. The manipulation of the argument dut_language leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-9348 1 Docker 1 Desktop 2026-04-15 N/A
Docker Desktop before v4.34.3 allows RCE via unsanitized GitHub source link in Build view.
CVE-2025-55903 2026-04-15 8.3 High
A HTML injection vulnerability exists in Perfex CRM v3.3.1. The application fails to sanitize user input in the "Bill To" address field within the estimate module. As a result, arbitrary HTML can be injected and rendered unescaped in client-facing documents.
CVE-2025-29366 2026-04-15 9.8 Critical
In mupen64plus v2.6.0 there is an array overflow vulnerability in the write_rdram_regs and write_rdram_regs functions, which enables executing arbitrary commands on the host machine.
CVE-2025-27109 2026-04-15 7.3 High
solid-js is a declarative, efficient, and flexible JavaScript library for building user interfaces. In affected versions Inserts/JSX expressions inside illegal inlined JSX fragments lacked escaping, allowing user input to be rendered as HTML when put directly inside JSX fragments. This issue has been addressed in version 1.9.4 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2024-36434 1 Supermicro 3 X11dph-i, X11dph-t, X11dph-tq 2026-04-15 7.5 High
An SMM callout vulnerability was discovered in Supermicro X11DPH-T, X11DPH-Tq, and X11DPH-i motherboards with BIOS firmware before 4.4.
CVE-2024-36433 1 Supermicro 3 X11dph-i, X11dph-t, X11dph-tq 2026-04-15 7.5 High
An arbitrary memory write vulnerability was discovered in Supermicro X11DPH-T, X11DPH-Tq, and X11DPH-i motherboards with BIOS firmware before 4.4.
CVE-2025-2521 2026-04-15 8.6 High
The Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution. Honeywell recommends updating to the most recent version of Honeywell Experion PKS: 520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1. The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
CVE-2025-2401 2026-04-15 N/A
Buffer overflow vulnerability in Immunity Debugger affecting version 1.85, its exploitation could allow a local attacker to execute arbitrary code, due to the lack of proper boundary checking.