| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Weak authentication issue exists in AE1021 firmware versions 2.0.10 and earlier and AE1021PE firmware versions 2.0.10 and earlier. If this vulnerability is exploited, the authentication may be bypassed with an undocumented specific string. |
| C300 information leak due to an analysis feature which allows extracting more memory over the network than required by the function. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
|
| Improper access control in the fTPM driver in the trusted OS could allow a privileged attacker to corrupt system memory, potentially leading to loss of integrity, confidentiality, or availability. |
| An insufficient DRAM address validation in PMFW may allow a privileged attacker to perform a DMA read from an invalid DRAM address to SRAM, potentially resulting in loss of data integrity. |
| C/sorting/binary_insertion_sort.c in The Algorithms - C through e5dad3f has a segmentation fault for deep recursion, which may affect common use cases such as sorting an array of 50 elements. |
| Improper access control in the ASP could allow a privileged attacker to perform an out-of-bounds write to a memory location not controlled by the attacker, potentially leading to loss of confidentiality, integrity, or availability. |
| An integer overflow in the ASP could allow a privileged attacker to perform an out-of-bounds write, potentially resulting in loss of data integrity. |
| There is an Out-of-bounds read vulnerability in TELLUS (v4.0.19.0 and earlier) and TELLUS Lite (v4.0.19.0 and earlier). If a user opens a specially crafted file, information may be disclosed and/or arbitrary code may be executed. |
| Airbyte is a data integration platform for ELT pipelines. Airbyte connection builder docker image is vulnerable to RCE via SSTI which allows an authenticated remote attacker to execute arbitrary code on the server as the web server user. The connection builder is used to create and test new connectors. Sensitive information, such as credentials, could be exposed if a user tested a new connector on a compromised instance. The connection builder does not have access to any data processes. This vulnerability is fixed in 0.62.2. |
| There are multiple stack-based buffer overflow vulnerabilities in V-SFT (v6.2.2.0 and earlier), TELLUS (v4.0.19.0 and earlier), and TELLUS Lite (v4.0.19.0 and earlier).
If a user opens a specially crafted file, information may be disclosed and/or arbitrary code may be executed. |
| Server receiving a malformed message that causes a disconnect to a hostname may causing a stack overflow resulting in possible remote code execution. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
|
| Buffer Overflow vulnerability in Neat Board NFC v.1.20240620.0015 allows a physically proximate attackers to escalate privileges via a crafted payload to the password field |
| Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.A remote code execution is possible due to an improper input validation.
This issue affects FLXEON: through 9.3.5. |
| A firmware bug which may lead to misinterpretation of data in the AMC2-4WCF and AMC2-2WCF allowing an adversary to grant access to the last authorized user. |
| Serviceware Processes 6.0 through 7.3 before 7.4 allows attackers without valid authentication to send a specially crafted HTTP request to a service endpoint resulting in remote code execution. |
| The ventilator's microcontroller lacks memory protection. An attacker could connect to the internal JTAG interface and read or write to flash memory using an off-the-shelf debugging tool, which could disrupt the function of the device and/or cause unauthorized information disclosure. |
| Insufficient Granularity of Access Control vulnerability in OpenText™ Service Management Automation X (SMAX), OpenText™ Asset Management X (AMX) allows Exploiting Incorrectly Configured Access Control Security Levels.This issue affects Service Management Automation X (SMAX) versions 2020.05, 2020.08, 2020.11, 2021.02, 2021.05, 2021.08, 2021.11, 2022.05, 2022.11; and Asset Management X (AMX) versions 2021.08, 2021.11, 2022.05, 2022.11.
|
| Misinterpretation of Input vulnerability in OpenText™ Service Management Automation X (SMAX), OpenText™ Asset Management X (AMX), and OpenText™ Hybrid Cloud Management X (HCMX) products. The vulnerability could allow Input data manipulation.This issue affects Service Management Automation X (SMAX) versions: 2020.05, 2020.08, 2020.11, 2021.02, 2021.05, 2021.08, 2021.11, 2022.05, 2022.11, 2023.05; Asset Management X (AMX) versions: 2021.08, 2021.11, 2022.05, 2022.11, 2023.05; and Hybrid Cloud Management X (HCMX) versions: 2020.05, 2020.08, 2020.11, 2021.02, 2021.05, 2021.08, 2021.11, 2022.05, 2022.11, 2023.05.
|
| CWE-1385 vulnerability in OpenText Documentum D2 affecting versions16.5.1 to CE 23.2. The vulnerability could allow upload arbitrary code and execute it on the client's computer.
|
| An issue in Vehicle Management System 7.31.0.3_20230412 allows an attacker to escalate privileges via the login.html component. |