Export limit exceeded: 425803 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (55490 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2026-11099 | 1 Chromium | 1 Chromium | 2026-06-09 | 6.5 Medium |
| A vulnerability flaw was found in the Skia component of the Chromium browser. Upstream bug(s): https://code.google.com/p/chromium/issues/detail?id=500414865 | ||||
| CVE-2026-36789 | 1 Tenda | 1 Ac1206 | 2026-06-09 | 7.5 High |
| Shenzhen Tenda Technology Co., Ltd Tenda AC1206 v15.03.06.23 was discovered to contain multiple stack overflows in the fromGstDhcpSetSer function via the username and password parameters. These vulnerabilities allow attackers to cause a Denial of Service (DoS) via a crafted HTTP request. | ||||
| CVE-2026-36786 | 1 Tenda | 1 Fh451 | 2026-06-09 | 7.5 High |
| Shenzhen Tenda Technology Co., Ltd Tenda FH451 V1.0.0.9 was discovered to contain a stack overflow in the list1 parameter of the fromDhcpListClient function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted HTTP request. | ||||
| CVE-2025-40936 | 1 Siemens | 1 Ps Iges Parasolid Translator Component | 2026-06-09 | 7.8 High |
| A vulnerability has been identified in PS/IGES Parasolid Translator Component (All versions < V29.0.258), Simcenter Femap (All versions < V2512.0003), Solid Edge (All versions < V226.00 Update 03). The affected applications contains an out of bounds read vulnerability while parsing specially crafted IGS files. This could allow an attacker to crash the application or execute code in the context of the current process. (ZDI-CAN-26755) | ||||
| CVE-2025-40798 | 1 Siemens | 3 Simatic, Simatic Pcs Neo, User Management Component | 2026-06-09 | 7.5 High |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition. | ||||
| CVE-2025-40797 | 1 Siemens | 3 Simatic, Simatic Pcs Neo, User Management Component | 2026-06-09 | 7.5 High |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition. | ||||
| CVE-2025-40796 | 1 Siemens | 3 Simatic, Simatic Pcs Neo, User Management Component | 2026-06-09 | 7.5 High |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition. | ||||
| CVE-2025-40795 | 1 Siemens | 3 Simatic, Simatic Pcs Neo, User Management Component | 2026-06-09 | 9.8 Critical |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a stack-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial of service condition. | ||||
| CVE-2023-46280 | 2026-06-09 | 6.5 Medium | ||
| A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions < V19 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions < V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions < V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions < V3.3.12), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2), SINEC NMS (All versions < V3.0 SP1). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel. | ||||
| CVE-2026-22164 | 1 Imaginationtech | 1 Graphics Ddk | 2026-06-09 | 7.5 High |
| Software installed and run as a non-privileged user may conduct improper GPU system calls to corrupt kernel heap memory. By creating resources of certain types and presenting a set of parameters to the affected interface the exploit can be used to corrupt kernel memory. | ||||
| CVE-2026-11024 | 4 Apple, Google, Linux and 1 more | 4 Macos, Chrome, Linux Kernel and 1 more | 2026-06-09 | 8.8 High |
| Stack buffer overflow in Skia in Google Chrome prior to 149.0.7827.53 allowed a remote attacker to potentially exploit stack corruption via a crafted HTML page. (Chromium security severity: Medium) | ||||
| CVE-2026-11096 | 4 Apple, Google, Linux and 1 more | 4 Macos, Chrome, Linux Kernel and 1 more | 2026-06-09 | 6.5 Medium |
| Out of bounds read in WebRTC in Google Chrome prior to 149.0.7827.53 allowed a remote attacker to obtain potentially sensitive information from process memory via a crafted HTML page. (Chromium security severity: Medium) | ||||
| CVE-2026-11124 | 4 Apple, Google, Linux and 1 more | 4 Macos, Chrome, Linux Kernel and 1 more | 2026-06-09 | 8.8 High |
| Integer overflow in Skia in Google Chrome prior to 149.0.7827.53 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page. (Chromium security severity: Medium) | ||||
| CVE-2026-46293 | 1 Linux | 1 Linux Kernel | 2026-06-09 | 7.1 High |
| In the Linux kernel, the following vulnerability has been resolved: clk: microchip: mpfs-ccc: fix out of bounds access during output registration UBSAN reported an out of bounds access during registration of the last two outputs. This out of bounds access occurs because space is only allocated in the hws array for two PLLs and the four output dividers that each has, but the defined IDs contain two DLLS and their two outputs each, which are not supported by the driver. The ID order is PLLs -> DLLs -> PLL outputs -> DLL outputs. Decrement the PLL output IDs by two while adding them to the array to avoid the problem. | ||||
| CVE-2026-11557 | 1 Tenda | 2 F451, F451 Firmware | 2026-06-08 | 8.8 High |
| A weakness has been identified in Tenda F451 1.0.0.7/1.0.0.9. The affected element is the function fromNatlimit of the file /goform/Natlimit of the component Web Management Interface. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks. | ||||
| CVE-2026-6274 | 1 Dts Electronics | 1 Redline Wr3200 | 2026-06-08 | 9.8 Critical |
| Improper Authentication, Missing authentication for critical function, Weak Authentication vulnerability in DTS Electronics Industry and Trade Ltd. Co. Redline WR3200 allows Accessing Functionality Not Properly Constrained by ACLs. This issue affects Redline WR3200: from 7.1.3 before 7.1.8. | ||||
| CVE-2026-48095 | 2 7-zip, Mcmilk | 2 7-zip, 7-zip | 2026-06-08 | 8.8 High |
| 7-Zip is a file archiver with a high compression ratio. Versions 26.00 and prior contain a heap buffer overflow vulnerability caused by an under-allocation in the NTFS compressed stream buffer (GetCuSize shift UB), potentially allowing attackers to cause arbitrary code execution or application crashes. CInStream::GetCuSize() in the NTFS handler computes the compression-unit buffer size as (UInt32)1 << (BlockSizeLog + CompressionUnit), and a crafted image with ClusterSizeLog >= 28 and CompressionUnit == 4 drives the exponent to 32, which is undefined behavior and collapses on x86/x64 so _inBuf is allocated as 1 byte. ReadStream_FALSE then writes up to 256 MB of attacker-controlled data into that 1-byte buffer in 64 KB iterations, and because the CInStream object sits only 304 bytes after _inBuf, its vtable pointer is overwritten and the next dispatched call achieves a vtable hijack. On 32-bit builds the overflow is unconditionally reached; on 64-bit it requires the parallel 8 GB _outBuf allocation to succeed, otherwise failing closed to denial of service. The NTFS handler is enabled by default in stock 7z.dll and, via signature-based fallback matching "NTFS " at offset 3, will open a crafted image regardless of file extension during extraction or testing. Version 26.01 fixes the issue. | ||||
| CVE-2026-36785 | 1 Tenda | 1 Fh451 | 2026-06-08 | 7.5 High |
| Shenzhen Tenda Technology Co., Ltd Tenda FH451 V1.0.0.9 was discovered to contain a stack overflow in the page parameter of the fromDhcpListClient function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted HTTP request. | ||||
| CVE-2026-11017 | 4 Apple, Google, Linux and 1 more | 4 Macos, Chrome, Linux Kernel and 1 more | 2026-06-08 | 6.5 Medium |
| Inappropriate implementation in Link Preview in Google Chrome prior to 149.0.7827.53 allowed a remote attacker who had compromised the renderer process to bypass navigation restrictions via a crafted HTML page. (Chromium security severity: Medium) | ||||
| CVE-2026-11019 | 1 Google | 2 Android, Chrome | 2026-06-08 | 6.5 Medium |
| Inappropriate implementation in Payments in Google Chrome on Android prior to 149.0.7827.53 allowed a remote attacker who had compromised the renderer process to perform domain spoofing via a crafted HTML page. (Chromium security severity: Medium) | ||||