| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TCM 4351B installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. |
| Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. |
| A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized administrative privileges when accessing to the charging station web server. |
| A CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting) through Cross-Site Request Forgery (CSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. |
| A CWE-79: Improper Neutralization of Input During Web Page Generation ('Stored Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause code injection when importing a CSV file or changing station parameters. |
| A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior) |
| A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges. |
| A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. |
| Fatek FvDesigner Version 1.5.76 and prior is vulnerable to an out-of-bounds write while processing project files, allowing an attacker to craft a special project file that may permit arbitrary code execution. |
| Cscape (All versions prior to 9.90 SP4) lacks proper validation of user-supplied data when parsing project files. This could lead to memory corruption. An attacker could leverage this vulnerability to execute code in the context of the current process. |
| UserExcelOut.asp within WebAccess/SCADA is vulnerable to cross-site scripting (XSS), which could allow an attacker to send malicious JavaScript code. This could result in hijacking of cookie/session tokens, redirection to a malicious webpage, and unintended browser action on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1). |
| The affected product is vulnerable to stack-based buffer overflow while processing over-the-air firmware updates from the CDN server, which may allow an attacker to remotely execute code on the SimpleLink Wi-Fi (MSP432E4 SDK: v4.20.00.12 and prior, CC32XX SDK v4.30.00.06 and prior, CC13X0 SDK versions prior to v4.10.03, CC13X2 and CC26XX SDK versions prior to v4.40.00, CC3200 SDK v1.5.0 and prior, CC3100 SDK v1.3.0 and prior). |
| Delta Electronics' CNCSoft ScreenEditor in versions prior to v1.01.30 could allow the corruption of data, a denial-of-service condition, or code execution. The vulnerability may allow an attacker to remotely execute arbitrary code. |
| Incorrect permissions are set to default on the ‘Project Management’ page of WebAccess/SCADA portal of WebAccess/SCADA Versions 9.0.1 and prior, which may allow a low-privileged user to update an administrator’s password and login as an administrator to escalate privileges on the system. |
| BB-ESWGP506-2SFP-T versions 1.01.09 and prior is vulnerable due to the use of hard-coded credentials, which may allow an attacker to gain unauthorized access and permit the execution of arbitrary code on the BB-ESWGP506-2SFP-T (versions 1.01.01 and prior). |
| Fatek FvDesigner Version 1.5.76 and prior is vulnerable to a stack-based buffer overflow while project files are being processed, allowing an attacker to craft a special project file that may permit arbitrary code execution. |
| CNCSoft-B Versions 1.0.0.3 and prior is vulnerable to an out-of-bounds write, which may allow an attacker to execute arbitrary code. |
| mySCADA myPRO: Versions 8.20.0 and prior has a feature where the API password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter. |
| Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0). |
| Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are vulnerable to multiple out-of-bounds write issues while processing project files, which may allow an attacker to execute arbitrary code. |