Search Results (95435 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-30349 1 Sscms 1 Siteserver Cms 2024-11-21 6.1 Medium
siteserver SSCMS 6.15.51 is vulnerable to Cross Site Scripting (XSS).
CVE-2022-30329 1 Trendnet 2 Tew-831dr, Tew-831dr Firmware 2024-11-21 9.8 Critical
An issue was found on TRENDnet TEW-831DR 1.0 601.130.1.1356 devices. An OS injection vulnerability exists within the web interface, allowing an attacker with valid credentials to execute arbitrary shell commands.
CVE-2022-30326 1 Trendnet 2 Tew-831dr, Tew-831dr Firmware 2024-11-21 5.4 Medium
An issue was found on TRENDnet TEW-831DR 1.0 601.130.1.1356 devices. The network pre-shared key field on the web interface is vulnerable to XSS. An attacker can use a simple XSS payload to crash the basic.config page of the web interface.
CVE-2022-30321 2 Hashicorp, Redhat 3 Go-getter, Openshift, Openstack 2024-11-21 8.6 High
go-getter up to 1.5.11 and 2.0.2 allowed arbitrary host access via go-getter path traversal, symlink processing, and command injection flaws. Fixed in 1.6.1 and 2.1.0.
CVE-2022-30318 1 Honeywell 4 Controledge Plc, Controledge Plc Firmware, Controledge Rtu and 1 more 2024-11-21 9.8 Critical
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service.
CVE-2022-30314 1 Honeywell 2 Safety Manager, Safety Manager Firmware 2024-11-21 4.6 Medium
Honeywell Experion PKS Safety Manager 5.02 uses Hard-coded Credentials. According to FSCT-2022-0052, there is a Honeywell Experion PKS Safety Manager hardcoded credentials issue. The affected components are characterized as: POLO bootloader. The potential impact is: Manipulate firmware. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 serial interface for firmware management purposes. When booting, the Safety Manager exposes the Enea POLO bootloader via this interface. Access to the boot configuration is controlled by means of credentials hardcoded in the Safety Manager firmware. The credentials for the bootloader are hardcoded in the firmware. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize these credentials to control the boot process and manipulate the unauthenticated firmware image (see FSCT-2022-0054).
CVE-2022-30311 1 Festo 16 Controller Cecc-x-m1, Controller Cecc-x-m1-mv, Controller Cecc-x-m1-mv-s1 and 13 more 2024-11-21 9.8 Critical
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-refresh-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CVE-2022-30310 1 Festo 16 Controller Cecc-x-m1, Controller Cecc-x-m1-mv, Controller Cecc-x-m1-mv-s1 and 13 more 2024-11-21 9.8 Critical
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-acknerr-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CVE-2022-30309 1 Festo 16 Controller Cecc-x-m1, Controller Cecc-x-m1-mv, Controller Cecc-x-m1-mv-s1 and 13 more 2024-11-21 9.8 Critical
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-off" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CVE-2022-30308 1 Festo 16 Controller Cecc-x-m1, Controller Cecc-x-m1-mv, Controller Cecc-x-m1-mv-s1 and 13 more 2024-11-21 9.8 Critical
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-on" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CVE-2022-30306 1 Fortinet 1 Fortiweb 2024-11-21 6.3 Medium
A stack-based buffer overflow vulnerability [CWE-121] in the CA sign functionality of FortiWeb version 7.0.1 and below, 6.4 all versions, version 6.3.19 and below may allow an authenticated attacker to achieve arbitrary code execution via specifically crafted password.
CVE-2022-30305 1 Fortinet 2 Fortideceptor, Fortisandbox 2024-11-21 3.6 Low
An insufficient logging [CWE-778] vulnerability in FortiSandbox versions 4.0.0 to 4.0.2, 3.2.0 to 3.2.3 and 3.1.0 to 3.1.5 and FortiDeceptor versions 4.2.0, 4.1.0 through 4.1.1, 4.0.0 through 4.0.2, 3.3.0 through 3.3.3, 3.2.0 through 3.2.2,3.1.0 through 3.1.1 and 3.0.0 through 3.0.2 may allow a remote attacker to repeatedly enter incorrect credentials without causing a log entry, and with no limit on the number of failed authentication attempts.
CVE-2022-30304 1 Fortinet 1 Fortianalyzer 2024-11-21 4.2 Medium
An improper neutralization of input during web page generation vulnerability [CWE-79] in FortiAnalyzer versions prior to 7.2.1, 7.0.4 and 6.4.8 may allow a remote unauthenticated attacker to perform a stored cross site scripting (XSS) attack via the URL parameter observed in the FortiWeb attack event logview in FortiAnalyzer.
CVE-2022-30303 1 Fortinet 1 Fortiweb 2024-11-21 8.6 High
An improper neutralization of special elements used in an os command ('OS Command Injection') [CWE-78] in FortiWeb 7.0.0 through 7.0.1, 6.3.0 through 6.3.19, 6.4 all versions may allow an authenticated attacker to execute arbitrary shell code as `root` user via crafted HTTP requests.
CVE-2022-30293 3 Debian, Redhat, Webkitgtk 4 Debian Linux, Enterprise Linux, Rhel Els and 1 more 2024-11-21 7.5 High
In WebKitGTK through 2.36.0 (and WPE WebKit), there is a heap-based buffer overflow in WebCore::TextureMapperLayer::setContentsLayer in WebCore/platform/graphics/texmap/TextureMapperLayer.cpp.
CVE-2022-30292 2 Fedoraproject, Squirrel-lang 2 Fedora, Squirrel 2024-11-21 10.0 Critical
Heap-based buffer overflow in sqbaselib.cpp in SQUIRREL 3.2 due to lack of a certain sq_reservestack call.
CVE-2022-30289 1 Citeum 1 Opencti 2024-11-21 5.4 Medium
A stored Cross-site Scripting (XSS) vulnerability was identified in the Data Import functionality of OpenCTI through 5.2.4. An attacker can abuse the vulnerability to upload a malicious file that will then be executed by a victim when they open the file location.
CVE-2022-30278 1 Synopsys 1 Black Duck Hub 2024-11-21 6.1 Medium
A vulnerability in Black Duck Hub’s embedded MadCap Flare documentation files could allow an unauthenticated remote attacker to conduct a cross-site scripting attack. The vulnerability is due to improper validation of user-supplied input to MadCap Flare's framework embedded within Black Duck Hub's Help Documentation to supply content. An attacker could exploit this vulnerability by convincing a user to click a link designed to pass malicious input to the interface. A successful exploit could allow the attacker to conduct cross-site scripting attacks and gain access to sensitive browser-based information.
CVE-2022-30274 1 Motorola 2 Ace1000, Ace1000 Firmware 2024-11-21 9.8 Critical
The Motorola ACE1000 RTU through 2022-05-02 uses ECB encryption unsafely. It can communicate with an XRT LAN-to-radio gateway by means of an embedded client. Credentials for accessing this gateway are stored after being encrypted with the Tiny Encryption Algorithm (TEA) in ECB mode using a hardcoded key. Similarly, the ACE1000 RTU can route MDLC traffic over Extended Command and Management Protocol (XCMP) and Network Layer (XNL) networks via the MDLC driver. Authentication to the XNL port is protected by TEA in ECB mode using a hardcoded key.
CVE-2022-30271 1 Motorola 2 Ace1000, Ace1000 Firmware 2024-11-21 9.8 Critical
The Motorola ACE1000 RTU through 2022-05-02 ships with a hardcoded SSH private key and initialization scripts (such as /etc/init.d/sshd_service) only generate a new key if no private-key file exists. Thus, this hardcoded key is likely to be used by default.