| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| ESPTouch is a connection protocol for internet of things devices. In the ESPTouchV2 protocol, while there is an option to use a custom AES key, there is no option to set the IV (Initialization Vector) prior to versions 5.3.2, 5.2.4, 5.1.6, and 5.0.8. The IV is set to zero and remains constant throughout the product's lifetime. In AES/CBC mode, if the IV is not properly initialized, the encrypted output becomes deterministic, leading to potential data leakage. To address the aforementioned issues, the application generates a random IV when activating the AES key starting in versions 5.3.2, 5.2.4, 5.1.6, and 5.0.8. This IV is then transmitted along with the provision data to the provision device. The provision device has also been equipped with a parser for the AES IV. The upgrade is applicable for all applications and users of ESPTouch v2 component from ESP-IDF. As it is implemented in the ESP Wi-Fi stack, there is no workaround for the user to fix the application layer without upgrading the underlying firmware. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.64), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.64), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.64), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.64), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.65), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.65), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.65), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.65), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.65), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.65), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.65), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.65), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.65), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.65), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.65), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.65), SIPROTEC 5 7SX85 (CP300) (All versions < V9.65), SIPROTEC 5 7UM85 (CP300) (All versions < V9.64), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.65), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.65), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.65), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.65), SIPROTEC 5 7VE85 (CP300) (All versions < V9.64), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.65), SIPROTEC 5 7VU85 (CP300) (All versions < V9.64), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.62), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.64). The affected devices are supporting weak ciphers on several ports (443/tcp for web, 4443/tcp for DIGSI 5 and configurable port for syslog over TLS).
This could allow an unauthorized attacker in a man-in-the-middle position to decrypt any data passed over to and from those ports. |
| A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain a weak encryption mechanism based on a hard-coded key.
This could allow an attacker to guess or decrypt the password from the cyphertext. |
| openwrt/asu is an image on demand server for OpenWrt based distributions. The request hashing mechanism truncates SHA-256 hashes to only 12 characters. This significantly reduces entropy, making it feasible for an attacker to generate collisions. By exploiting this, a previously built malicious image can be served in place of a legitimate one, allowing the attacker to "poison" the artifact cache and deliver compromised images to unsuspecting users. This can be combined with other attacks, such as a command injection in Imagebuilder that allows malicious users to inject arbitrary commands into the build process, resulting in the production of malicious firmware images signed with the legitimate build key. This has been patched with 920c8a1. |
| Weak algorithm used to sign RPM package. The following products are affected: Acronis Cyber Protect Cloud Agent (Linux) before build 39185, Acronis Cyber Protect 16 (Linux) before build 39938. |
| A vulnerability has been found in running-elephant Datart up to 1.0.0-rc3. Affected by this issue is the function getTokensecret of the file datart/security/src/main/java/datart/security/util/AESUtil.java of the component API. The manipulation leads to use of hard-coded cryptographic key
. The attack is possible to be carried out remotely. The attack is considered to have high complexity. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. |
| Agentflow developed by Flowring has an Use of Hard-coded Cryptographic Key vulnerability, allowing unauthenticated remote attackers to exploit the fixed key to generate verification information, thereby logging into the system as any user. Attacker must first obtain an user ID in order to exploit this vulnerability. |
| A vulnerability was detected in nocobase up to 1.9.4/2.0.0-alpha.37. The affected element is an unknown function of the file nocobase\packages\core\auth\src\base\jwt-service.ts of the component JWT Service. The manipulation of the argument API_KEY results in use of hard-coded cryptographic key
. The attack can be launched remotely. A high complexity level is associated with this attack. The exploitability is described as difficult. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was determined in opsre go-ldap-admin up to 20251011. This issue affects some unknown processing of the file docs/docker-compose/docker-compose.yaml of the component JWT Handler. Executing manipulation of the argument secret key can lead to use of hard-coded cryptographic key
. The attack can be launched remotely. Attacks of this nature are highly complex. The exploitability is assessed as difficult. The exploit has been publicly disclosed and may be utilized. |
| A vulnerability was detected in PandaXGO PandaX up to fb8ff40f7ce5dfebdf66306c6d85625061faf7e5. This affects an unknown function of the file config.yml of the component JWT Secret Handler. The manipulation of the argument key results in use of hard-coded cryptographic key
. The attack may be performed from remote. This attack is characterized by high complexity. The exploitability is reported as difficult. The exploit is now public and may be used. This product utilizes a rolling release system for continuous delivery, and as such, version information for affected or updated releases is not disclosed. The project was informed of the problem early through an issue report but has not responded yet. |
| A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). Affected devices only provide weak password obfuscation. An attacker with network access could retrieve and de-obfuscate the safety password used for protection against inadvertent operating errors. |
| SmartOS, as used in Triton Data Center and other products, has static host SSH keys in the 60f76fd2-143f-4f57-819b-1ae32684e81b image (a Debian 12 LX zone image from 2024-07-26). |
| gitoxide is an implementation of git written in Rust. Before 0.42.0, gitoxide uses SHA-1 hash implementations without any collision detection, leaving it vulnerable to hash collision attacks. gitoxide uses the sha1_smol or sha1 crate, both of which implement standard SHA-1 without any mitigations for collision attacks. This means that two distinct Git objects with colliding SHA-1 hashes would break the Git object model and integrity checks when used with gitoxide. This vulnerability is fixed in 0.42.0. |
| Use of hard-coded cryptographic key vulnerability in i-PRO Configuration Tool affects the network system for i-PRO Co., Ltd. surveillance cameras and recorders. This vulnerability allows a local authenticated attacker to use the authentication information from the last connected surveillance cameras and recorders. |
| An issue was discovered in Kaseya Rapid Fire Tools Network Detective through 2.0.16.0. A vulnerability exists in the EncryptionUtil class because symmetric encryption is implemented in a deterministic and non-randomized fashion. The method Encrypt(byte[] clearData) derives both the encryption key and the IV from a fixed, hardcoded input by using a static salt value. As a result, identical plaintext inputs always produce identical ciphertext outputs. This is true for both FIPS and non-FIPS generated passwords. In other words, there is a cryptographic implementation flaw in the password encryption mechanism. Although there are multiple encryption methods grouped under FIPS and non-FIPS classifications, the logic consistently results in predictable and reversible encrypted outputs due to the lack of per-operation randomness and encryption authentication. |
|
A hard-coded AES key vulnerability was reported in the Motorola GuideMe application, along with a lack of URI sanitation, could allow for a local attacker to read arbitrary files.
|
| The Use of a Hard-coded Cryptographic Key vulnerability in Juniper Networks Juniper Cloud Native Router (JCNR) and containerized routing Protocol Deamon (cRPD) products allows an attacker to perform Person-in-the-Middle (PitM) attacks which results in complete compromise of the container.
Due to hardcoded SSH host keys being present on the container, a PitM attacker can intercept SSH traffic without being detected.
This issue affects Juniper Networks JCNR:
* All versions before 23.4.
This issue affects Juniper Networks cRPD:
* All versions before 23.4R1. |
| The devices are vulnerable to an authentication bypass due to flaws in the authorization mechanism. An unauthenticated remote attacker could exploit this weakness by performing brute-force attacks to guess valid credentials or by using MD5 collision techniques to forge authentication hashes, potentially compromising the device. |
| The JWT secret key is embedded in the egOS WebGUI backend and is readable to the default user. An unauthenticated remote attacker can generate valid HS256 tokens and bypass authentication/authorization due to the use of hard-coded cryptographic key. |
| Inadequate encryption strength issue exists in SS1 Ver.16.0.0.10 and earlier (Media version:16.0.0a and earlier). If this vulnerability is exploited, a function that requires authentication may be accessed by a remote unauthenticated attacker. |