| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP >= 6.4.1. |
| A vulnerability has been found in Tenda i24, 4G03 Pro, 4G05, 4G08, G0-8G-PoE, Nova MW5G and TEG5328F up to 65.10.15.6. Affected is an unknown function of the component Shadow File. Such manipulation with the input Fireitup leads to hard-coded credentials. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. |
| A vulnerability has been found in TOZED ZLT M30S and ZLT M30S PRO 1.47/3.09.06. Affected is an unknown function of the component Web Interface. Such manipulation leads to hard-coded credentials. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| IBM Sterling Connect:Direct for UNIX Container 6.3.0.0 through 6.3.0.6 Interim Fix 016, and 6.4.0.0 through 6.4.0.3 Interim Fix 019 IBM® Sterling Connect:Direct for UNIX contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. |
| A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.
Other related CVE's are CVE-2025-14095 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required Configuration for Exposure:
Attacker requires physical access to the analyzer.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication. |
| Zohocorp's ManageEngine Analytics Plus and Zoho Analytics on-premise versions older than 6130 are vulnerable to an AD only account takeover because of a hardcoded sensitive token. |
| Certain models of routers from Billion Electric has hard-coded embedded linux credentials, allowing attackers to log in through the SSH service using these credentials and obtain root privilege of the system. |
| Use of Hard-coded Credentials vulnerability in GoodWe Technologies Co., Ltd. GW1500‑XS allows anyone in physical proximity to the device to fully access the web interface of the inverter via Wi‑Fi.This issue affects GW1500‑XS: 1.1.2.1. |
| In Eaton X303 3.5.16 - X303 3.5.17 Build 712, an attacker with network access to a XC-303 PLC can login as root over SSH. The root password is hardcoded in the firmware. NOTE: This vulnerability appears in versions that are no longer supported by Eaton. |
| IXON B.V. IXrouter IX2400 (Industrial Edge Gateway) v3.0 was discovered to contain hardcoded root credentials stored in the non-volatile flash memory. This vulnerability allows physically proximate attackers to gain root access via UART or SSH. |
| ui/pref/ProxyPrefView.java in weasis-core in Weasis 4.5.1 has a hardcoded key for symmetric encryption of proxy credentials. |
| "Piccoma" App for Android and iOS versions prior to 6.20.0 uses a hard-coded API key for an external service, which may allow a local attacker to obtain the API key. Note that the users of the app are not directly affected by this vulnerability. |
| Forever KidsWatch Call Me KW50 R36_YDR_A3PW_GM7S_V1.0_2019_07_15_16.19.24_cob_h, and Forever KidsWatch Call Me 2 KW60 R36CW_YDE_S4_A29_2_V1.0_2023.05.24_22.49.44_cob_b have a Hardcoded password vulnerability. |
| The configuration file is encrypted with a static key derived from a
static five-character password which allows an attacker to decrypt this
file. The application hashes this five-character password with
the outdated and broken MD5 algorithm (no salt) and uses the first five
bytes as the key for RC4. The configuration file is then encrypted with
these parameters. |
| Use of hard-coded credentials issue exists in Ricoh Streamline NX PC Client ver.3.7.2 and earlier. If this vulnerability is exploited, an attacker may obtain LocalSystem Account of the PC where the product is installed. As a result, unintended operations may be performed on the PC. |
| Hard-coded Credentials in CoolKit eWeLlink app are before 5.4.x on Android and IOS allows local attacker to unauthorized access to sensitive data via Decryption algorithm and key obtained after decompiling app
|
| The application uses several hard-coded credentials to encrypt config files during backup, to decrypt the new firmware during an update and some passwords allow a direct connection to the database server of the affected device. |
| Use of Hard-coded Credentials in Kiloview NDI allows un-authenticated users to bypass authenticationThis issue affects Kiloview NDI N3, N3-s, N4, N20, N30, N40 and was fixed in Firmware version 2.02.0227 .
|
| A vulnerability in the .sdd file allows an attacker to read default passwords stored in plain text within the code. By exploiting these plaintext credentials, an attacker can log into affected SICK products as an “Authorized Client” if the customer has not changed the default password. |
| Use of Hard-coded Credentials vulnerability in Baicells Snap Router BaiCE_BMI on EP3011 (User Passwords modules) allows unauthorized access to the device. |