| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability was found in D-Link DIR-513 up to 20190831. It has been declared as critical. This vulnerability affects the function formSetWanDhcpplus of the file /goform/formSetWanDhcpplus. The manipulation of the argument curTime leads to buffer overflow. The attack can be initiated remotely. This vulnerability only affects products that are no longer supported by the maintainer. |
| Improper handling of direct memory writes in the input-output memory management unit could allow a malicious guest virtual machine (VM) to flood a host with writes, potentially causing a fatal machine check error resulting in denial of service. |
| CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that
could allow an unauthorized attacker to modify configuration values outside of the normal range when the
attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web
interface functionality. |
| Buffer Overflow vulnerability in osrg gobgp commit 419c50dfac578daa4d11256904d0dc182f1a9b22 allows a remote attacker to cause a denial of service via the handlingError function in pkg/server/fsm.go. |
| A remote unauthenticated attacker may use default certificates to generate JWT Tokens and gain full access to the tool and all connected devices. |
| During a short time frame while the device is booting an unauthenticated remote attacker can send traffic to unauthorized networks due to the switch operating in an undefined state until a CPU-induced reset allows proper configuration. |
| Improper Access Control in an on-chip debug interface could allow a privileged attacker to enable a debug interface and potentially compromise data confidentiality or integrity. |
| @solana/web3.js is the Solana JavaScript SDK. Using particular inputs with `@solana/web3.js` will result in memory exhaustion (OOM). If you have a server, client, mobile, or desktop product that accepts untrusted input for use with `@solana/web3.js`, your application/service may crash, resulting in a loss of availability. This vulnerability is fixed in 1.0.1, 1.10.2, 1.11.1, 1.12.1, 1.1.2, 1.13.1, 1.14.1, 1.15.1, 1.16.2, 1.17.1, 1.18.1, 1.19.1, 1.20.3, 1.21.1, 1.22.1, 1.23.1, 1.24.3, 1.25.1, 1.26.1, 1.27.1, 1.28.1, 1.2.8, 1.29.4, 1.30.3, 1.31.1, 1.3.1, 1.32.3, 1.33.1, 1.34.1, 1.35.2, 1.36.1, 1.37.3, 1.38.1, 1.39.2, 1.40.2, 1.41.11, 1.4.1, 1.42.1, 1.43.7, 1.44.4, 1.45.1, 1.46.1, 1.47.5, 1.48.1, 1.49.1, 1.50.2, 1.51.1, 1.5.1, 1.52.1, 1.53.1, 1.54.2, 1.55.1, 1.56.3, 1.57.1, 1.58.1, 1.59.2, 1.60.1, 1.61.2, 1.6.1, 1.62.2, 1.63.2, 1.64.1, 1.65.1, 1.66.6, 1.67.3, 1.68.2, 1.69.1, 1.70.4, 1.71.1, 1.72.1, 1.7.2, 1.73.5, 1.74.1, 1.75.1, 1.76.1, 1.77.4, 1.78.8, 1.79.1, 1.80.1, 1.81.1, 1.8.1, 1.82.1, 1.83.1, 1.84.1, 1.85.1, 1.86.1, 1.87.7, 1.88.1, 1.89.2, 1.90.2, 1.9.2, and 1.91.3. |
| A vulnerability, which was classified as critical, was found in H3C GR-3000AX up to V100R006. Affected is the function EnableIpv6/UpdateWanModeMulti/UpdateIpv6Params/EditWlanMacList/Edit_List_SSID of the file /goform/aspForm of the component HTTP POST Request Handler. The manipulation of the argument param leads to buffer overflow. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. Other functions might be affected as well. |
| Improper Encoding or Escaping of Output vulnerability in The Wikimedia Foundation Mediawiki - Confirm Account Extension allows Cross-Site Scripting (XSS).This issue affects Mediawiki - Confirm Account Extension: from 1.39 through 1.43. |
| The JTAG interface of Wattsense Bridge devices can be accessed with physical access to the PCB. After connecting to the interface, full access to the device is possible. This enables an attacker to extract information, modify and debug the device's firmware. All known versions are affected. |
| A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1. |
| A vulnerability classified as critical has been found in GL.iNet GL-A1300 Slate Plus, GL-AR300M16 Shadow, GL-AR300M Shadow, GL-AR750 Creta, GL-AR750S-EXT Slate, GL-AX1800 Flint, GL-AXT1800 Slate AX, GL-B1300 Convexa-B, GL-B3000 Marble, GL-BE3600 Slate 7, GL-E750, GL-E750V2 Mudi, GL-MT300N-V2 Mango, GL-MT1300 Beryl, GL-MT2500 Brume 2, GL-MT3000 Beryl AX, GL-MT6000 Flint 2, GL-SFT1200 Opal, GL-X300B Collie, GL-X750 Spitz, GL-X3000 Spitz AX, GL-XE300 Puli and GL-XE3000 Puli AX 4.x. Affected is an unknown function of the file plugins.so of the component RPC Handler. The manipulation leads to buffer overflow. It is recommended to upgrade the affected component. |
| In BootROM, there is a missing size check for RSA keys in Certificate Type 0 validation. This could lead to memory buffer overflow without requiring additional execution privileges. |
| In FDL1, there is a possible missing payload size check. This could lead to memory buffer overflow without requiring additional execution privileges. |
| In BootRom, there's a possible missing payload size check. This could lead to memory buffer overflow without requiring additional execution privileges. |
| The redirect_to method in Rails allows provided values to contain characters which are not legal in an HTTP header value. This results in the potential for downstream services which enforce RFC compliance on HTTP response headers to remove the assigned Location header. |
| On-chip debug and test interface with improper access control in some 4th Generation Intel(R) Xeon(R) Processors when using Intel(R) SGX or Intel(R) TDX may allow a privileged user to potentially enable escalation of privilege via local access. |
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. |
| An issue was discovered in the Vector Skin component for MediaWiki before 1.39.5 and 1.40.x before 1.40.1. vector-toc-toggle-button-label is not escaped, but should be, because the line param can have markup. |